From SketchUp or Revit to a printed scale model: what we change in an architect's file
A SketchUp model rarely prints as it stands. The usual blocker is thickness: a 60 mm mullion at 1:200 becomes 0.3 mm, thinner than the 0.4 mm nozzle we print through, so it simply never appears. Before anything goes on a machine we close the surfaces into solids, thicken what is too fine and delete what nobody will see.
We open architects' files most weeks. They come from SketchUp, Revit and Rhino, sent by design offices in Dubai and across the UAE, by developers' in-house teams, and by exhibition contractors who need a model standing in a sales centre by a given date. The geometry is usually good. It was built for a different purpose.
A presentation model answers what the building looks like from here. A printable model has to answer where the plastic is and where the air is, at every point, with nothing ambiguous in between.
What actually arrives in an architect's file
The most common file we get was drawn to be rendered. The building is a skin: click a wall and there is nothing behind the face, because no camera was going round there. Window frames are rectangles pushed a few millimetres into that skin rather than solid profiles. Glazing is a field of loose panels. The ground is draped geometry with an open underside.
A render engine punishes none of that, which is why it is there. Rebuilding it is our work, not a complaint about the drawing.
Structure is the other thing that arrives. SketchUp files come nested: groups inside components inside groups, ten levels down, the facade sitting in something called "Copy of Group#47". Revit goes the other way and exports thousands of separate bodies, one per family instance, every door handle among them.
Then the world origin. A model placed on real survey coordinates sits kilometres from 0,0,0, where SketchUp handles small faces worse, so coincident faces and gaps appear in parts of the file that were clean near the origin. We move the model back and set units to millimetres first.
SketchUp 3D printing starts with the solid test
SketchUp's own definition of solid is strict, and it is the fastest check available. Geometry has to sit inside a group or component, and every edge must be shared by exactly two faces. Loose geometry can never be solid, however clean it looks.
Select the group and open Entity Info. "Solid Group" or "Solid Component" means printable in principle. Plain "Group" means something is open, usually a missing face at the bottom of a wall, a leftover internal face from a push/pull, or a stray edge in a corner. The free Solid Inspector extension finds and marks them, which beats hunting by eye.
Export runs through File, then Export, then 3D Model, with STL as the type. The Options button is the part people skip: it holds the export units, a binary or ASCII choice, and a checkbox for exporting only the current selection. Use that checkbox. If the tower, the podium and the base are separate groups, they reach us as separate files instead of one merged lump.
Revit to 3D print: export the view, not the project
Revit writes STL natively, through File, then Export, then CAD Formats, then STL. That has been in the product since the 2021.1 release, so the add-in advice still circulating online applies only to older versions. The export runs from whichever 3D view is active, with resolution, units and a binary or ASCII choice in the dialogue, and it only ever carries what that view shows.
That is where the mistake happens, not in finding the command. Export the whole project and you get the structural frame, every duct run, the furniture families and whatever context was loaded: hundreds of megabytes that still contain no printable building.
What works is a dedicated 3D view for printing. Turn off the categories nobody will see, crop the site with a section box, set detail to coarse or medium, then export that view. Revit geometry is parametric and usually comes out as closed solids, so the failure here is volume rather than open surfaces, the opposite of what SketchUp sends.
If you can share the native file or an IFC as well, send it. Changing a wall thickness in the model takes minutes. Changing it in a triangle mesh takes an afternoon.
STL export for architecture: units, resolution and what to send with it
STL stores a surface and nothing else: no units, no colour, no part names. A file drawn in feet and opened as millimetres lands 304.8 times out, and a tower the size of a sugar cube is a familiar sight on the bench in our Dubai workshop. 3MF keeps units and separate parts in one file, so use it if your export dialogue offers it.
Export deviation is the other setting worth a second. Too coarse and a dome prints as a faceted lampshade. Too fine and the file swells to hundreds of megabytes for no visible gain. Between 0.01 and 0.05 mm covers most model work. Our checklist for preparing a file before you send it has the rest.
Put the overall dimensions in the message too: height, width, depth, in millimetres. That line removes every scaling question before it starts.
Scale model wall thickness: the arithmetic that decides what survives
Divide the real dimension by the scale. That is the whole method, and it settles most arguments before they begin.
- A 60 mm aluminium mullion is 0.3 mm at 1:200 and 0.6 mm at 1:100.
- A 1.1 m balustrade with 20 mm balusters gives 22 mm of height and 0.4 mm posts at 1:50.
- A 140 mm parapet edge reads as 0.7 mm at 1:200.
- A 30 mm facade reveal is 0.15 mm at 1:200, which is less than one layer.
Set those against what the machines hold. FDM here runs through a 0.4 mm nozzle, and below roughly 0.8 mm a wall stops being dependable: it comes off the bed looking fine, then snaps when the supports are cleaned or the crate moves. For anything that gets sanded, which on a presentation model is every visible face, we want 1.2 mm or more. Resin reaches further down, to features near 0.5 mm.
So at 1:200 that mullion becomes a line rather than a part. We cut it as a shallow groove, let paint carry it, or drop it. At 1:100 it can exist in resin, if someone is going to study that elevation up close.
Thickening has a cost nobody raises at the start: it changes the elevation. Raise 0.3 mm mullions to a printable 1.2 mm and the facade grows ribs it never had. So we keep every second mullion at printable width instead of fattening all of them, and the rhythm still reads from a metre away. Balustrades go the other way: a solid band with the correct top line, painted a dark value, reads as open railing better than a row of broken posts. How the scale itself gets chosen sits in our piece on printed architectural scale models.
What we delete, and why interiors are wasted print time
Interior partitions, furniture, ceilings and services go first on any model with an opaque shell. The slicer still processes all of it, so print time and material pay for geometry nobody will ever see. The exception is a cutaway, a lift-off roof or a lit model, and that has to be said at the start, because cavities and cable routes need to exist before we split anything.
Entourage goes too. Imported people and cars are often the heaviest objects in the file by triangle count, and detailed tree meshes get replaced with bought model-making trees, which look better at 1:200 than anything printed. Context buildings outside the plot get flattened to massing blocks.
Printed text has its own floor. Below about 2 mm cap height on FDM, letters stop reading and turn into a textured smear, so building names and plot numbers get painted, applied as cut vinyl, or engraved into the base.
Architectural model file prep: what we change and what we ask first
The first question is always the scale, or the finished height if the scale is still open. Everything after it follows: which elements survive, which machine prints them, whether the model comes in one piece, how big the crate is.
Then we ask which elevation matters most, so supports land on a face nobody studies. Whether the model has to come apart, for shipping or for a phasing presentation. Whether anything is lit. And who signs off on geometry changes.
On our side the work is predictable:
- Single-surface walls get a thickness.
- Curtain wall grids get welded into one panel with a recessed glazing plane, usually painted rather than printed clear, since printed clear plastic reads as frosted instead of glass.
- Thin elements get raised to the minimum or handed to resin.
- Shells get hollowed with internal ribs rather than printed as solid blocks.
- The bottom gets a flat face so the model stands without a jig.
Work here runs from 5 cm figures to constructions reaching 15 m, and anything past a single build volume gets printed in parts and joined into one object, so a 1 m tower arrives as several stacked pieces. Cut planes follow something the eye already expects: a floor slab, a setback, a shadow line under a cornice. Put the joint there and primer closes it. Run it across a blank facade and the line stays visible however much filler goes on. The planes go to the architect as an image first, because a joint crossing a feature the office spent a month on is not ours to decide quietly.
We also confirm which file is final. A facade revision arriving after a section is printed sends that section back on a machine and then back to bare plastic. The reprint costs machine time. The refinishing costs a person at a bench with 320 grit, and more printers cannot speed that up.
FDM for the mass, resin for the fine work
Most architectural models we build in Dubai come off both machines. FDM carries the bulk of the volume, where a layer line disappears under primer. Resin takes the pieces that would otherwise print as a blur: balustrades, louvre fins, tracery.
The trade is toughness. Resin parts are harder and snap rather than bend, so a drop onto a tiled floor usually ends them. On a model heading for a stand we keep resin off the exposed corners and take coarser detail in exchange for a model that survives the week.
What we check before the first part goes on a machine
Watertightness is the first gate, and repair tools handle simple cases on their own. After that we take cross sections at a few heights and look at what the walls actually are: a facade that looked solid in the viewport is often a surface with nothing behind it, and a section cut shows that in a second. Then a thickness check across the model, to catch anything under the minimum.
Part count is the last number, because two hundred small components means two hundred cleanups and two hundred placements by hand. Then the model goes on screen at print size. If a detail is invisible there, it will be invisible in plastic.
Send the file, or a massing sketch if the model is not finished, through the contact form or on WhatsApp, and we will come back on what changes and what your geometry takes.
FAQ
Can you print a SketchUp model as it is?
Sometimes, if it was built as solids. Check each group in Entity Info: "Solid Group" or "Solid Component" means printable in principle, plain "Group" means something is open. Most presentation models need work first, usually giving single-surface walls a thickness. Send the .skp with the STL, since fixing the original file beats repairing a mesh.
How should a Revit model be exported for printing?
Build a separate 3D view for it. Turn off the categories nobody will see, crop the site with a section box, set detail to coarse or medium, then export through File, Export, CAD Formats, STL, with units in millimetres. Exporting the whole project gives a very large file that is still not printable. Send the native .rvt or an IFC alongside it.
Why do thin elements disappear at model scale?
Because the printer has a physical minimum and the drawing does not. A 60 mm mullion at 1:200 works out at 0.3 mm, well under the 0.4 mm nozzle we print through on FDM and below the roughly 0.8 mm that survives sanding. Resin reaches around 0.5 mm, which is why railings and louvres either go to resin or become a groove or a painted line.
Which file format should I send?
3MF if your software offers it, because it carries units and separate parts in one file. STL works everywhere but stores only the surface, so write the overall dimensions in the message. Native files, STEP or IFC are welcome in addition, since they let us change geometry rather than patch triangles.
Do you change the architect's geometry, and do we see it first?
Yes to both. Thickening, welding curtain wall grids, hollowing shells, deleting interiors and placing cut planes all change the model, and some of those changes show in the finished piece. Anything that affects how the building reads, which mullions survive, where a joint runs, goes back to the office as an image first. The parts nobody sees, internal ribs and registration keys, we handle without asking.